Cardiac troponin I Western blot set

 

DATA SHEET

This data sheet is provided for information only.
Please contact our Customer Service for further information and pricing.

Open the printable PDF-file

Cardiac troponin I Western blot set
Cat.# 9CT4

Contents:
Mouse anti-troponin I  MAb and human cardiac TnI electrophoresis sample
 
MAb: 
4C2

MAb isotypes:
IgG2a

MAb specificity:
Cardiac isoform of troponin I from different mammalian species.
Please see HyTest Markers of Cardiovascular Disease catalogue for cross-reactivity information.

MAb purification: 
Chromatography on protein A Sepharose

MAb presentation: 
1 x 1 mg vial, in PBS, pH 7.4, 0.1 % sodium azide (NaN3)

Antigen: 
Human cardiac troponin I

Antigen source: 
Human cardiac tissue.
Blood sample from the tissue donor was tested and found negative for HBsAg, HIV-1 and HIV-2 antibodies, HCV, and syphilis.

Antigen presentation: 
1 x 5 µg vial, lyophilized from protein solution in 250 mM Tris-HCl, pH 6.8, 8% SDS, 40% sucrose,
4% 2-mercaptoethanol, 0.1% bromophenole blue.

Antigen reconstitution: 
Dissolving in 5 mM 2-mercaptoethanole solution with gentle, but thorough shaking.

Set applications: 
Cardiac troponin I immunodetection in Western blotting and DOT blot, using Troponin I sample as internal standard or calibrator.

Sample preparation: 
MAb 4C2 is ready to use in Western blotting. Recommended working concentration is 5 µg/ml.
Antigen is ready to use after reconstitution. The vial contains 5 µg of human cardiac troponin I. Add 50 µl of 5 mM 2-mercaptoethanole into the vial and dissolve the pellet with gentle stirring. After dissolving centrifuge the vial briefly to collect all the liquid to the bottom of the vial.

Storage: 
MAb + 4 °C 
Antigen -20 °C

Material safety note: 
This product is sold for research use only. Standard Laboratory Practices should be followed when handling this material. Antibody preparation contains sodium azide (0.1 %) as preservative. Although the amount of sodium azide is very small appropriate care must be taken when handling this product.

Warranty and limitation of liability: 
HyTest LTD makes no warranty of any kind, expressed or implied, including warranty of merchantability or fitness for any particular purpose. Data provided with the product is only guideline on how the product may perform in your system. Since every diagnostic system depends on many reagents, it is impossible to predict with any accuracy how our product will react in your system.

References:
Search Troponin I references from PubMed.
See all Troponin References

Related products:
See other cardiac and blood coagulation products

Kauppalehti AchievementISO 9001